Interfaces |
36.4 GB drives |
Dual-ported 10K and 15K RPM FC-AL FS-SCA-2 (3.5-in.) |
73.4 GB drives |
Dual-ported 10K RPM FC-AL FS-SCA-2 (3.5-in.) |
181.6 GB drives |
Dual-ported 7200 RPM FC-AL FS-SCA-2 (3.5-in.) |
Capacity and Performance |
|
3910 |
3960 |
Power receptacles required |
(US) Two NEMA L6-30P for 200-240 VAC
(International) Two 32A, single phase IEC 309 connected to 220-240 VAC |
(US) Two per cabinet NEMA L6-30P for 200-240 VAC
(International) Two per cabinet 32A, single phase IEC 309 connected to 240-240 VAC |
36.4 GB drives |
2.6 TB max cabinet (72 drives) |
2.6 TB max cabinet (72 drives)
5.8 TB max system (total of 162 drives with expansion cabinet) |
73.4 GB drives |
5.2 TB max cabinet (72 drives) |
5.2 TB max cabinet (72 drives)
11.8 TB max system (total of 162 drives with expansion cabinet) |
181.6 GB drives |
13.0 TB max cabinet (72 drives) |
13.0 TB max cabinet (72 drives)
29.3 TB max system (total of 162 drives with expansion cabinet) |
Host Connectivity |
Supported host bus adapters |
Sun StorEdge 1 Gb and 2 Gb PCI single Fibre Channel network adapters
Sun StorEdge 1 Gb and 2 Gb PCI dual Fibre Channel network adapters
Sun StorEdge SBUS dual Fibre Channel network adapter
Sun StorEdge cPCI dual Fibre Channel network adapter
Emulex LP8000-F1/N1* (Windows environment)
QLogic QLA2200F/66* (Linux environment)
|
Note: *All non-Sun host bus adapters supported by third-party vendor. |
Host connect |
F port (Fabric Port) |
Maximum hosts* |
3910 |
3960 |
*Two connections per host |
4 (direct connect) |
7 (direct connect) |
Software |
Supported Software |
Sun StorEdge Availability Suite software
Sun StorEdge Utilization Suite software
Sun StorEdge Performance Suite software
Sun StorEdge Resource Management Suite software
Sun StorEdge Traffic Manager software
Solstice DiskSuite[tm] 4.2.1 software
VERITAS Volume Manager 3.2 software
VERITAS NetBackup 3.4 software
Solstice Backup[tm] 6.0 software or later
Sun Cluster 3.0 update 2 software
VERITAS Cluster Server 2.0 software
|
Hardware Platforms |
Supported hardware |
Sun Enterprise[tm] 220R, 250, 420R, 450, 3500-6500, and 10000 servers
Sun Fire[tm] 280R, V480, V880, 3800, 4800, 4810, 6800, 12K, and 15K servers
|
|
3910 |
3960 |
Maximum logical device support |
64 LUNs |
144 LUNs |
Environment |
AC power |
200-240 VAC @ 47-53 Hz single phase |
|
3910 |
3960 |
Heat output maximum |
~14,000 BTU |
~14,000 BTU |
Note: ~26,000 BTU for Sun StorEdge 3960 system with expansion cabinet |
Temperature-operating |
5º C to 35º C (41º F to 95º F) |
Temperature-nonoperating |
-20º C to 60º C (-4º F to 140º F) |
Shock-operating |
4.0 g for maximum duration of 11 ms (half-sinewave) |
Shock-nonoperating |
10.0 g for maximum duration of 11 ms (half-sinewave) X, Y, and Z axis |
Vibration-operating |
5 to 500 Hz @ 0.25 g sinusoidal |
Vibration-nonoperating |
5 to 500 Hz @ 1.0 g sinusoidal |
Humidity-operating |
20% to 80% RH, noncondensing, max gradient 10% per hour |
Humidity-nonoperating |
5% to 93% RH, noncondensing, max gradient 10% per hour |
Altitude-operating |
-1000 ft. to + 10,000 ft. (-305 m to 3048 m) |
Altitude-nonoperating |
-1000 ft. to + 40,000 ft. (-305 m to 12,192 m) |
Regulations |
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950, EN60950, IEC950 CB Scheme with all country deviations, IEC825-1, 2, and CFR21 Part 1040 |
Ergonomics |
EK1-ITB-2000 |
RFI/EMI |
EN55022/CISPR22 Class A, FCC CFR47, Part 15 Class A, EN61000-3-2, EN61000-3-3 |
Immunity |
EN55024 |
Regulatory Markings |
CE, FCC-A, ICES-003-A, C-tick, VCCI-A, GOST-R, BSMI-A, MIC, UL/cUL, TUV-GS |
Dimensions and Weights |
|
3910 |
3960 |
Height |
1905 mm (75 in.) |
1905 mm (75 in.) |
Width |
607.1 mm (23.9 in.) |
1214.1 mm (47.8 in.) |
Depth |
939.8 mm (37 in.) |
939.8 mm (37 in.) |
Weight |
665 kg (1465 lb.) |
1295 kg (2855 lb.) |